Power Connection Kitのメーカーや取扱い企業、製品情報、参考価格、ランキングをまとめています。
イプロスは、 製造業 BtoB における情報を集めた国内最大級の技術データベースサイトです。

Power Connection Kit - メーカー・企業と製品の一覧

Power Connection Kitの製品一覧

1~11 件を表示 / 全 11 件

表示件数

Power Connection Kit 'C-150-E'

Introducing the Raychem industrial heating cable and power cable straight connection kit.

The "C-150-E" is a kit for the straight connection of Raychem industrial heating cables: BTV, QTVR, XTV, KTV, and power cables. It can be installed under insulation materials that do not require heating treatment and is suitable for applications with a temperature range of -40°C to 215°C. Please use three-core twisted wire cables with an outer diameter of 7.8mm to 12.5mm. The power cable and heater leads, as well as the blades, are connected with butt splice terminals. 【Features】 ■ Can be installed under insulation materials that do not require heating treatment ■ Usable for applications with a temperature range of -40°C to 215°C *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-03-26_15h54_27.png
  • 2020-03-26_15h54_30.png
  • Other machine elements

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Power Connection Kit "JB-82"

Four input ports! Can be used for power connection, linear connection, and T-type connection of Reikem's self-regulating heating cable.

The "JB-82" is a connection kit for general locations. It can be used for power connections, linear connections, and T-type connections of Raichem's self-regulating heating cables. With four entry ports, the heating cable itself can connect up to four cables, or it can connect one power supply line and up to three heating cables. For connections with the heating cable, use C25-100 or C25-21. 【Specifications (Enclosure)】 ■ Protection rating: IP66 ■ Entry ports: 4M20/25 ■ Exposure temperature: -35℃ to +115℃ ■ Body: Glass fiber reinforced polycarbonate (gray) ■ Cover: Polycarbonate (gray) ■ Gasket cover: Made of polyurethane ■ Body weight: Approximately 450g *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-03-26_15h56_04.png
  • Other machine elements

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Power Connection Kit "JBU-100"

We provide rapid construction, safety, reliability, and maintenance-free solutions!

The "JBU-100" is designed to connect up to three Raychem industrial heating cables: BTV, QTVR, XTV, KTV, and VPL to a power supply. The innovative WAGO cage clamp terminal block offers rapid installation, safety, reliability, and maintenance-free operation. It can be used for power connections, straight connections, and T-type connections of Raychem self-regulating heating cables. 【Features】 ■ Provides rapid installation, safety, reliability, and maintenance-free operation ■ Can be used for power connections, straight connections, and T-type connections of Raychem self-regulating heating cables ■ With four entry points, it allows for the connection of up to four heating cables or the connection of three heating cables with a power supply line *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-03-26_15h57_53.png
  • Other machine elements

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Power Connection Kit "C25-21"

We support Raychem heating cables BTV, QTVR, XTV, KTV, and VPL.

The "C25-21" is a kit for connecting Raychem heating cables BTV, QTVR, XTV, KTV, and VPL to a junction box. This product maintains electrical insulation of the heater's lead wires and heating element, using Raychem's heat shrink tubing for sealing the core part of the heater. Please note that the junction box requires either an M25 screw hole or a φ25 hole, and if using a φ25 hole, a lock nut is needed. 【Features】 ■ Compatible heating cables: BTV, QTVR, XTV, KTV, VPL ■ Screw size: M25×1.5 (if there is no screw hole in the junction box, a φ25 hole is required) ■ Minimum operating ambient temperature: -55℃ ■ Maximum exposure temperature (ground part): 110℃ ■ Weight: 60g *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-03-26_15h45_59.png
  • Other machine elements

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Power Connection Kit 'C25-100'

This is an introduction to the kit for connecting Raychem heating cables to the junction box.

The "C25-100" is a kit for connecting Raychem heating cables to a junction box. This product maintains the electrical insulation of the heater's conductors and the core seal does not require heat treatment, making installation easy. Please note that the junction box requires either an M25 screw hole or a φ25 hole, and if using a φ25 hole, a lock nut is needed. 【Features】 ■ Compatible heating cables: BTV, QTVR, XTV, KTV, VPL ■ Screw size: M25×1.5 (if there is no screw hole in the junction box, a φ25 hole is required) ■ Minimum operating ambient temperature: -55℃ ■ Maximum exposure temperature (ground part): 110℃ ■ Weight: 70g *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-03-26_15h49_12.png
  • Other machine elements

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Power Connection Kit "JS-100-A"

This is an introduction to a kit for connecting the power supply of a single Raychem self-regulating heating cable.

The "JS-100-A" is a kit for connecting the power supply of a single Raychem self-regulating heating cable. It combines a connection kit and an insulation entry kit, and the robust stand protects the heating cable while allowing installation of insulation materials up to 100mm thick. It uses a new type of core seal boot that does not require a heat gun or torch during installation. Therefore, there is no need to confirm the use of heat sources or open flames. 【Features】 ■ The robust stand protects the heating cable ■ Allows installation of insulation materials up to 100mm thick ■ Uses a new type of core seal boot ■ Does not require a heat gun or torch during installation ■ The sealing material inside the boot does not harden, making installation and maintenance easy *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-03-26_15h52_11.png
  • Other machine elements

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Power Connection Kit "JBS-100"

Insulation material with a thickness of up to 100mm can be installed! No heat gun or torch is required during installation.

The "JBS-100" is a power connection kit specifically designed for a single Raychem self-regulating heating cable and Raychem power-limiting cable. Additionally, it is a product that combines the connection kit and insulation entry kit. The robust stand protects the heating cable and can be installed with insulation up to 100mm thick. 【Features】 ■ The robust stand protects the heating cable ■ Can be installed with insulation up to 100mm thick ■ Uses a new type of core seal boot ■ No heat gun or torch required during installation ■ The sealing material inside the boot does not harden, making installation and maintenance easy *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-03-26_16h08_09.png
  • Other machine elements

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Power Connection Kit for Domestic Explosion-Proof System 'JBM-100'

Heaters can be connected up to three units! They can be applied in domestic Class 1 and Class 2 hazardous locations, as well as in Type 1 and Type 2 hazardous areas.

This kit can be applied to domestic Class 1 and Class 2 hazardous locations or first and second category hazardous areas, and it can connect up to three heaters. It is a power connection kit specifically for up to three Raychem self-regulating heating cables and Raychem power-limiting cables. Additionally, it combines the connection kit with an insulation entry kit, and the robust stand protects the heating cables, allowing installation with insulation materials up to 100mm thick. 【Features】 - Up to three heaters can be connected - Applicable to domestic Class 1 and Class 2 hazardous locations, first and second category hazardous areas - Power connection kit specifically for up to three Raychem self-regulating heating cables and Raychem power-limiting cables - The robust stand protects the heating cables - Can be installed with insulation materials up to 100mm thick *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-03-26_16h09_20.png
  • Other machine elements

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Power Connection Kitの関連カテゴリ